Tech Specs
- Power supply:
- PoE+
- Supply Voltage:
- up to 48 V DC (commonly 12 V DC, managed by PoE+ switch)
- Power consumption:
- 2-3 W (idle) | 11 W (maximum)
- Temperature:
- -20 °C to +50 °C
- Case:
- RAL 7016 anthrazite grey, different sizes available
- CPU:
- ARM Cortex-A53
- Microprocessor:
- 1200 Mhz
- Cores:
- 4
- RAM:
- 1 GB of LPDDR2-SDRAM
- Storage:
- 32 GB eMMc storage
- Supports:
- BLE, NFC
Installation Tips
The Elevator Control Unit components must be powered with POE+ 802.3at.
Internet connectivity must be provided in a dedicated VLAN, exclusively for Sensorberg devices.
Installation requires a trailing cable.
Check out the Elevator Control Hub installation guide:
Electrical Connections
Terminal | Function |
---|---|
1-16 |
30 VDC, 2 A (resistive)
110 VDC, 0.3 A (resistive) 125 VAC, 0.5 A (resistive)
NO (Normally Open)
NC (Normally Closed) |
Use Cases
Option 1
Elevator Control Hub components move together with the elevator car*.
*Both AHP and Extension Hub require a network cable with PoE.
Option 2
Elevator Control Hub components in separate locations (in elevator car and elevator control room)*.
*AHP and Extension Hub require to be connected to LAN via trailing cable
- Access Hub Protect (Part 1 - acting components)
- Access Hub Protect (Part 2 - external reader)
- Extension Hub
- Elevator electronics option board
- Elevator control panel
Relevant Links
For the Elevator Control Hub installation guide, please contact support@sensorberg.com.