Product Detail

Access Hub Protect



Tech Specs

Indoor Unit

Power supply:
PoE+
Supply Voltage:
up to 48 V DC (commonly 12 V DC, managed by PoE+ switch)
Power consumption:
2-3 W (idle) | 11 W (maximum)
Temperature:
-20 °C to +50 °C
Case:

Indoor unit:
2 parts, RAL 7016 anthrazite grey

External unit (reader):
Surface mounted or in flush mounted socket

External reader is connected via a 5m prefabricated cable to securely placed acting components.

CPU:
ARM Cortex-A53
Microprocessor:
1200 Mhz
Cores:
4
RAM:
1 GB of LPDDR2-SDRAM
Storage:
32 GB eMMc storage
Supports:
BLE, NFC

Outdoor Unit

LED:
3 RGB LEDs for status indication
Supports:
BLE, NFC

Dimensions

Indoor Unit

External Reader


How it works


Electrical Connections

Terminal Function
1 V in (Up to 48 V)
2 V out (potential free contact 1 | max. 1200 mA)
3 V out (potential free contact 2 | max. 1200 mA)
4 V out (potential free contact 3 | max. 1200 mA)
5 12 V out for indication signal
6 Indication NO
7 Indication NC
8 Optional V in (change jumper position*)
9 12 V switchable power output (max. 1200 mA)
10 GND
11 12V power output (max. 1 A)
JP1 Jumper for door opener supply
*Left: Normal mode 12 V out on terminal 9. Terminal 8 not used
Right: Optional V in from terminal 8 used for door opener supply on terminal 9

Installation Tips

The external reader has to be connected via a 5m prefabricated cable to securely placed internal acting components.

The reader can be installed in a Ø 68mm flush mounted socket*.

Network traffic has to be routed in a separate VLAN, exclusive for Sensorberg devices.

A Building Hub in the server room connected in the same VLAN increases security of the solution even further.

Building Hub

Check out the Access Hub Protect installation guide:

Access Hub Protect Installation Guide

*NOT compatible with Ø 60 mm cement flush mounted sockets.


Supported Door Locks

Electrical Strikes

The Sensorberg Access Hub supports all doors that open with a 12 V - 24 V switchable signal (e.g. door buzzer).

It also works with motorized locks up to 48 V, as long as they open with the dry contact.

Motorised locks, intercom and other locks

The Sensorberg Access Hub connects to motorised locks and bell systems via a potential free contact.

All locks that open with a potential free contact for opening are supported by the Sensorberg hardware.

The maximum voltage input for dry contact openings is 48 V.