Tech Specs
- Power supply:
- PoE+
- Supply voltage:
- up to 48 V DC (commonly 12 V DC, managed by PoE+ switch)
- Power consumption:
- 2-3 W (idle) | 11 W (maximum)
- Temperature:
- -20 °C to +50 °C
- Case:
- 2 parts:
Front: RAL 7016 matte anthrazite grey
Back: Semi-transparent
- CPU:
- ARM Cortex-A53
- Microprocessor:
- 1200 Mhz
- Cores:
- 4
- RAM:
- 1 GB of LPDDR2-SDRAM
- Storage:
- 4/8/16/32 GB eMMc storage
- Supports:
- BLE, NFC
Dimensions
Electrical Connections
Terminal | Function |
---|---|
1 | V in (Up to 48 V) |
2 | V out (dry contact 1 | max. 1200 mA) |
3 | V out (dry contact 2 | max. 1200 mA) Please consult with Sensorberg before utilising |
4 | V out (dry contact 3 | max. 1200 mA) |
5 | 12 V out for indication signal |
6 | Indication NO |
7 | Indication NC |
8 | Optional V in (change jumper position*) |
9 | 12 V switchable power output (max. 1200 mA) |
10 | GND |
11 | 12V power output (max. 1 A) |
JP1 | Jumper for door opener supply |
*Left: Normal mode 12V out on terminal 9. Terminal 8 not used Right: Optional V in from terminal 8 used for door opener supply on terminal 9 |
Installation Tips
The access hub will be powered with a POE+ 802.3at.
Network traffic has to be routed in a separate VLAN, exclusive for Sensorberg devices.
A Building Hub in the server room connected in the same VLAN increases security of the solution even further.
For the Access Hub installation guide, please contact support@sensorberg.com.
Supported Door Locks
Electrical Strikes
The Sensorberg Access Hub supports all doors that open with a 12 V - 24 V switchable signal (e.g. door buzzer).
It also works with motorized locks up to 48 V, as long as they open with the dry contact.
Motorised locks, intercom and other locks
The Sensorberg Access Hub connects to motorised locks and bell systems via a dry contact.
All locks that open with a dry contact for opening are supported by the Sensorberg hardware.
The maximum voltage input for dry contact openings is 48 V.